C. Sign Design

C1: The sign function … concepts and types

What is a sign? This guideline explains the purpose of signs and lists the various types. It also includes descriptions of the methods and construction and types of support.

C2: Design considerations

C2.1: Legibility and visibility

A sign may be visible at a considerable distance but may not be legible until the observer is much closer. Parameters such as letter height, letter style and colour, which affect legibility, are discussed. Colour and brightness of illumination, which affect night time legibility, are also mentioned.

C2.2: Internal illumination of Signs

The purpose of this note is to highlight common issues with all internally illuminated signs and to explain how they may be used to design a well illuminated sign. The remaining parts of C2.2 deal with specific sign designs and lamp types.

C2.2 (a): Internal Illumination of Box signs

The purpose of this note is to list the factors which contribute to light output and evenness of illumination in box signs, and to show how they may be used to design a well illuminated sign. It should be read in conjunction with Guideline C2.2 Introduction to Internally Illuminated Signs. Each source type will be dealt with in turn.

C2.2 (b): Internal Illumination of Individual Letters and logos

This Technical Guideline considers the type and layout of light sources within individual letter signs and logos to obtain satisfactory internal illumination of the faces and sides of those letters. Consideration is also given to the design of layouts within halo letters.  This Guideline should be read in conjunction with C2.2 Internal Illumination of Signs.

C2.2(c): Light Emitting Diodes (LED)

This Technical Guideline is now published as Guideline C4 LED Guideline and C5 LED Flexface Report.

C2.3: External illumination (floodlighting)

C2.3 (a): General criteria

This guideline discusses the differences between internal illumination of signs and external illumination by means of floodlighting. It suggests applications where floodlighting may be suitable and mentions its advantages and disadvantages.

C2.3 (b): Compact luminaires

Floodlighting of a sign may be obtained by using compact luminaires spaced at regular intervals along the top or bottom of a sign. Starting with the published performance figures for a luminaire, this guideline provides a method of calculating the illumination of the various parts of a sign.

C2.3(c): Slim luminaires

THIS GUIDELINE IS NO LONGER AVAILBLE

 

C2.3 (d): Linear reflectors

There are a variety of slim luminaires that include reflectors and/or prismatic diffusers to improve the forward distribution of the light from the fluorescent lamps. This guideline shows how the sign illumination may be calculated, starting with published performance figures for the luminaire.

C2.4: Animation

This guideline discusses various types of sign animation and how they have been achieved. Starting with early mechanical devices, the various steps leading to semiconductor switching of the sign components are listed. Deriving the flashing sequence requires various semiconductor circuits, ranging from simple on/off oscillators to full computer control with the sequence determined by software.

C2.5: Structural design

C2.5 (a): Poles and structures

This Technical Guideline is in the course of preparation

 

C2.5 (b): Acrylic panel structural design

Plastic face panels of signs are subject to wind pressure (see Guideline K13.1). Depending on the dimensions of the face area, the thickness of the panel must be chosen to reduce the deflection (due to wind forces) to acceptable limits. This guideline describes a method for calculating the deflection using the characteristics of the chosen plastics material.

C2.5(c): Retaining plastic sign panels

Signs may have face panels made from single sheets of plastics material. The face panels for large signs may be made up using several sheets, fitted end to end. In either case, the method of supporting the panels has to cope with wind pressures, etc. and with the fact that the linear expansion of the plastics material may be quite different from that of the housing. This guideline shows various methods of supporting the panels to ensure safe retention.

C2.6: Electrical design

Signs must be safe electrically and this guideline discusses the various methods of achieving safety. These include passive protection (enclosures, clearances, etc.) and active protection by means of earth-leakage and open-circuit protection. The guideline also discusses the choice of tube diameters and number of lines of tubing from sign letters of various heights

C2.7 Hot and Cold cathode lighting design

This guideline shows how to calculate room illuminance from room dimensions and lamp light output. It also suggests lamp arrangements to ensure even illumination.

C2.8: Fire safety design

This Technical Guideline is in the course of preparation

 

C2.9: RNIB Series

C2.9(a): Signage (this is an RNIB document)

Guidance to make signs clear and easy to read

C2.9(b): Lighting (this is an RNIB document)

Guidance to make the lighting of signs produce the clarity needed for the visually impaired

C2.9(c): Visual Contrast (this is an RNIB document)

Guidance on visual contrast of signs and how to make the most of residual vision

C3: Variable information signs

Most modern variable information signs are produced by means of dot-matrix arrangements. Various methods of producing a dot matrix (electro-mechanical, liquid crystal, fibre optics and LEDs) are discussed. Some historical notes on earlier methods of varying displays are also mentioned. Methods of inputting data and transmitting that data to the display are also listed.

C4: LED guideline

A history and guide to the development and correct use of LEDs within the Sign Industry

C5: LED Flexface Report

LED back lighting of flexface signs as an alternative to fluorescent tubes