BS:559 GUIDANCE CENTRE
BS 559 Guidance Centre
The BS 559 series sets out good practice for signs across their whole lifecycle, from design and installation through to inspection and maintenance.
This Guidance Centre brings together BSGA information, guidance and resources to help members and the wider industry understand the standards and what they mean in practice.
The BS 559 series:
- BS 559-1:2023 Interior and exterior signs – Design, manufacture and installation of signs – Specification
- BS 559-2:2026 Interior and exterior signs – Part 2: Inspection and maintenance – Specification, published 19th November 2026
Together, these two standards provide a framework for good practice throughout the lifecycle of a sign.
What is BS 559-2?
BS 559-2 addresses the inspection and maintenance of signs once they are installed, providing a structured approach to their ongoing management
throughout their service life.
It covers illuminated and non-illuminated signs, fixed and portable signs, digital displays and electronically changeable signs. Road traffic, fire safety, railway trackside and airside airport signs are excluded, as these are covered by other standards and guidance.
Key points:
- A risk-based approach. The extent and frequency of inspection are informed by the type, location, age and condition of the sign, its exposure to the environment, accessibility and the risks associated with the installation.
- Regular physical inspection. The standard requires a minimum of one on-site inspection a year, or within 12 months of installation or the previous inspection. Inspections consider the sign, its fixings, foundations, electrical systems, supporting structure and the surface to which it is attached.
- Existing signs. Where the installation date, service life or previous inspection records cannot be established, an enhanced inspection regime may be needed to assess the sign’s condition and identify potential risks.
- Competence. Those carrying out inspections need the appropriate knowledge, skills, experience and equipment for the sign and the work involved. This may include competence in working at height, electrical safety and structural inspection, depending on the inspection required.
- The sign holder. This is the person or organisation that assumes legal responsibility for a sign once it is in place. Depending on the circumstances, this could be a building owner, occupier, tenant or another appointed party.
- Responsibilities in writing. Where responsibility is shared, for example between a landlord and tenant, arrangements for sign safety, inspection and maintenance should be clearly established in writing, such as through a lease or management agreement.
- Handover and records. At handover, the principal contractor and/or supplier should provide details of the recommended inspection frequency, scope of inspection and maintenance requirements. Keeping records of inspections, findings and maintenance helps build a history of the sign and informs its ongoing management.
What it means for you:
- Sign companies: Review your handover information and ensure you have the appropriate competence and equipment for any inspection work you undertake.
- Building owners, landlords, tenants and facilities managers: Establish which signs you are responsible for, where they are located, how they are constructed, when they were installed and their current condition.
- Specifiers and architects: Consider inspection and maintenance requirements from the outset, as part of the sign’s whole lifecycle.
BSGA resources:
The BSGA is developing guidance and resources to help members and the wider industry understand BS 559-2 and put the standard into practice.
- BS 559 podcast series: Four episodes exploring British Standards, the BS 559 series, the practical implications of inspection and maintenance, and responsibility for signs.
Watch the series on YouTube - BSGA Bulletin articles: Further reading on understanding BS 559-2 and putting the standard into practice.
Why British Standards Matter to Signmakers
What Does BS559-2 Mean for Signmakers
Public Consultation on BS 559-2 Closes on 25th August
BSGA Welcomes Public Consultation on BS559-2
Press releases and industry coverage:
- BSGA welcomes publication of BS 559-2:2026 –
Read BSGA press release, 19th November 2026 - BSGA keeping the industry informed –
Signlink, 27th July 2026
Signlink, 28th September 2026
Further guidance, articles and briefings will be added to this page as they become available.
Get the standard:
BS 559-2:2026 is available from the British Standards Institution (BSI). Purchase the Standard.
Questions:
For further information about BS 559-2, or to speak to a member of the BSGA team, contact ask@uksigns.org.
Free BS 559-2 resources to download:
Practical tools to help you put BS 559-2 into practice, whether you’re responsible for signs or inspecting them.
Sign holder checklist:
For building owners, landlords, tenants and facilities teams.
A one-page check of your signs, responsibilities, inspections and records, with space to agree follow-up actions.
Sign inspection record:
For sign companies and inspectors.
A one-page record for each sign, covering every key check, the overall condition, defects found and sign-off, ready to hand to the sign holder.
These resources are practical aids and do not replace BS 559-2:2026, which is available from BSI.