K: Legislation and standards

K1: The Control of Advertisements Regulations

Many signs, particularly those that are illuminated, are subject to planning regulations. This guideline lists the regulations which apply in the four countries of the United Kingdom. It also provides details of reference sources, where copies of the regulations and related guides can be obtained. For a more detailed review of the country specific regulations see guidelines K1.1, K1.2, K1.3 and K1.4.

K1.1: The Control of Advertisements Regulations – England

Many signs, particularly those that are illuminated, are subject to planning regulations. This guideline outlines the requirements of The Town and Country Planning (Control of Advertisements) (England) Regulations 2007 as amended by The Town and Country Planning (Control of Advertisements) (England) (Amendment) Regulations 2007 and discusses the types of sign allowed under ‘deemed consent’.

K1.2: The Control of Advertisements Regulations – Wales

This guideline outlines the requirements of The Town and Country Planning (Control of Advertisements) Regulations 1992 as amended by The Town and Country Planning (Control of Advertisements) (Amendment) Regulations 1994 and 1999 and discusses the types of sign allowed under ‘deemed consent’.

K1.3: The Control of Advertisements Regulations – Scotland

This Technical Guideline is not yet available.

 

K1.4: The Control of Advertisements Regulations – Northern Ireland

This Technical Guideline is not yet available.

 

K2: The brightness of illuminated advertisements (ILE Report N05)

The institution of Lighting Engineers (ILE) publish a report (No5) listing recommendations for the brightness (luminance) of signs. The permitted levels are dependent on the size of the sign and the type of neighbourhood where the sign is installed. Many local authorities use this report in assessing the suitability of signs for planning purposes.

K2.1 - GUIDANCE ON PLG05

K3 -BS EN 50107- Overview

K3.1 British Standard BS EN 50107-1:2002

Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV. General requirements.

K3.2 British Standard BS EN 50107-2-2019 Jan

Signs and luminous-discharge-tube installations operating from a no-load rated output voltage exceeding 1 kV but not exceeding 10 kV. Requirements for earth-leakage and open-circuit devices.

K3.3 British standard BS EN 50107-3:2018

Product standard covering luminous signs with discharge lamps and/or LED (light emitting diodes) and/or EL (electroluminescent) lightsources with a nominal voltage not exceeding 1000 V, with the exclusion of general lighting, traffic- or emergency related purpose.

K4: British Standard BS 559: ‘Specification for the design, construction and installation of signs’

The requirements for the design, manufacture and installation of signs are specified in BS 559. The standard specifies materials and procedures necessary for making safe signs. For an explanation of the requirements of BS 559, see guideline K4.1.

K4.1: A guide to British Standard BS 559:2009 (updated)

This guideline examines the clauses of BS 559 and explains the thinking behind the clauses and procedures for compliance.

K5: British Standard BS EN 50143: ‘Cables for signs and luminous-discharge-tube installations operating from a no-load output voltage exceeding 1 kV but not exceeding 10 kV’

BS EN 50107 specifies which types of cable insulation and protection shall be used for various types of sign installations. This standard specifies the characteristics and construction of the permitted cables.

K5.1 Guidance notes on BS EN 50143 DEC 2016

Guidance note for BS EN 50143 compiled in December 2016

K6: British Standard BS7671 The IET Wiring Regulations

The requirements for the mains supply, including cabling, switchgear and protection are specified in the Wiring Regulations of the Institution of Electrical Engineers (BS7671). For an explanation of the requirements of BS7671, see guideline K6.1.

K6.1: British Standard BS7671, 2008 Including Amendment No. 3:2015 - The IET Wiring Regulations 17th Edition

This guideline examines the clauses of the IEE Wiring Regulations (BS7671) and explains the thinking behind the clauses and procedures for compliance.

K7: British Standard BS 4533 (EN 60598): ‘Luminaires’ (i.e. low-voltage signs)

Signs, other than those operating at high voltage are classified as luminaires and are specified in much the same way as any other lighting fitting. The general requirements are specified in BS EN 60598-1 with specific requirements specified in the various sections of Part 2. In particular, Part 2.1 specifies fixed signs and Part 2.4 specifies portable signs.

K7.1: A Guide to British Standard BS 4533 (EN 60598)

This guideline examines the clauses of BS EN 60598 and explains the thinking behind the clauses and procedures for compliance. Most of the notes concern conformance to Part 1 but there are also notes on Parts 2.1 and 2.4.

K8: Fire Regulations

As part of the Building Regulations, signs attached to buildings should be made from materials having low flammability. The way in which this might be achieved and the appropriate standards are discussed in this guideline.

K9: A guide to the Electricity at Work Regulations

For safe working with electricity, manufacturers and contractors must conform to the Electricity at Work Regulations. The Health and Safety Executive (HSE) publish guidance notes explaining the requirements. This guideline lists the address of HSE Books where the guidance notes may be obtained.

K10: CE marking

All signs and sign installations have to conform to the appropriate EU directives. This guideline explains what these are and how signs that are electrical products have to be CE marked indicating conformance. This guideline should be read in conjunction with K10.1, K10.2 and K10.3.

K10.1: Technical documentation supporting a CE mark

Two types of documentation are needed to support a CE mark; a declaration of conformity and a technical construction file. This guideline explains the significance of this documentation and how a sign manufacturer should produce the documents.

K10.2: A guide to the Electromagnetic Compatibility Directive (EMCD)

A sign or sign installation has to conform to the electromagnetic compatibility directive (EMCD). This guideline explains what is meant by the EMCD and the requirements and means to ensure conformance.

K10.3: A guide to the Low Voltage Directive (LVD)

A sign or sign installation has to conform to the Low Voltage Directive (LVD). This guideline explains what is meant by the LVD and the requirements and means to ensure conformance.

K11: The Construction (Design and Management) Regulations

The Construction (Design and Management) Regulations 2007 (CDM) came into force on 6th April 2007. They revise and bring together the CDM Regulations 1994 and the Construction (Health Safety and Welfare) Regulations 1996 into a single regulatory package.

K12: British Standard BS EN 60529: ‘Degrees of protection provided by enclosures (IP code)’

The degree of protection provided by an enclosure is specified as an IP code of two numbers. The first number specifies the degree of protection against solid objects and hence gives an indication of electrical safety. The second number specifies the degree of protection against the ingress of water. The guideline should be read in conjunction with K12.1.

K13: British Standard BS 6399: ‘Loading for buildings’ Part 2: ‘Code of practice for wind loads’

Wind loadings on signs can be destructive and it is important to know the wind forces that may be encountered in a particular location. BS 6399 provides a method of calculating the wind force. This guideline, which should be read in conjunction with K13.1, provides the scope of the standard and lists where copies may be purchased.

K13.1: A guide to British Standard BS 6399, Part 2

This guideline takes a step-by-step look at the calculations specified in BS 6399 and explains the significance of each calculation.

K14: European voltage harmonisation (LIF Technical Statement 15)

This Guideline has now been withdrawn.

 

K15: Use of energy efficient ballasts

There is an EU requirement for the use of energy efficient fluorescent lamp ballasts. Over time, the less efficient ballasts are being phased out. This guideline lists the long term requirements and correlates these against the known performance of various types of ballast, including high-frequency ballasts.

K16: Measurements Units Style Guide

K17: Construction Industry Scheme (CIS): Guidance Notes:

This Guideline is now published under Section B – Commercial Factors and renumbered
B9 :Construction Industry Scheme (CIS) Guidance Notes.

K18: Vehicle Wrapping

This Guideline is now published under Section D – Sign Manufacture and renumbered D4: Vehicle Wrapping

 

K19: Risk Assessment And Method Statements (Rams)

Risk Assessment and Method Statements (RAMS) have been around for a while and are now an integral part to the design, manufacture process. Sign & graphics companies must demonstrate that they have assessed the processes involved, identified risks and how these risks can be managed and reduced when possible.